EEPROM or Electrically Erasable Programmable Read Only Memory is usually an add-on memory module that is used to back up the main program in CMOS RAM of the processor. In many cases, the processor can be programmed to load the EEPOM's program to RAM if RAM is lost or corrupted.
Input Module There are many types of input modules to choose from. The type of input module used is dependent upon what real world input to the PLC is desired. Some examples of inputs are limit switches, electric eyes, and pushbuttons. DC inputs, such as thumbwheel switches, can be used to enter integer values to be manipulated by the PLC. DC input cards are used for this application. Since most industrial power systems are inherently noisy, electrical isolation is provided between the input and the processor. Electromagnetic interference (EMI) and Radio Frequency Interference (RFI) can cause severe problems in most solid state control systems. The component used most often to provide electrical isolation within I/O cards is called an optical isolator or optocoupler. The wiring of an input is not complex. The object is to get a voltage at a particular point on the card. Typically there are 8 to 32 input points on any one input module. Each point will be assigned a unique address by the processor. Analog input modules are special input cards that use analog to digital conversion (A to D) to sense variables such as temperature, speed, pressure, and position. The external device normally is connected to a controller (transducer) producing an electrical signal the analog input card can interpret. This signal is usually 4 to 20 Ma or a 0 to 10 volt signal.
Output Module Output modules can be for used for ac or dc devices such as solenoids, relays, contractors, pilot lamps, and LED readouts. Output cards usually have from 6 to 32 output points on a single module. The output device within the card provides the connection from the user power supply to the load. Usually silicon controlled rectifiers (SCR), triac, or dry contact relays are use for this purpose. Individual outputs are rated most often at 2 to 3 amperes. Output cards, like input cards have electrical isolation between the load being connected and the PLC. Analog output cards are a special type of output modules that use digital to analog conversion (D to A). The analog output module can take a value stored in a 12 bit file and convert it to an analog signal. Normally this signal is 0 -10 volts dc or 4 to 20 Ma. This analog signal is often used in equipment such as motor operated valves and pneumatic position control devices.
|
|